 BTE6000 / PTU6000...CS Series
Submersible precision stainless steel transmitters
FEATURES * 0...100 mbar to 0...10 bar, 0...2 to 0...150 psi gage or absolute * For corrosive media * 0...10 V, 1...6 V, 0...20 mA or 4...20 mA output * Field interchangeable * For harsh environments
MEDIA COMPATIBILITY
Wetted materials: stainless steel 1.4404 (316L), PVC, PUR, NBR11 Housing: protection class IP 68 (according to DIN EN 60529) respectively NEMA 6P1
ELECTRICAL CONNECTION
0...10 V, 1...6 V output
+Vs red Vout yellow -Vs black bare 13 to 30 V
SPECIFICATIONS9,10
Maximum ratings Supply voltage (reverse polarity protection) 13...30 V BTE(M)/PTU6...0..., 1... 12...36 V BTE(M)/PTU6...4..., 5...2 Maximum load current BTE(M)/PTU6...0..., 1... Temperature limits Storage Operating Compensated Vibration (5 to 500 Hz) Mechanical shock Proof pressure3
sensor
V
GND
0...20 mA output
+Vs red Iout blue -Vs black bare 12 to 36 V
sensor
10 mA
RL
V
GND
-40 to 85C -25 to 85C 0 to 70C 10 gRMS 50 g 2 x rated pressure
4...20 mA output
+Vs red sensor -Vs black bare
V
12 to 36 V
RL GND
August 2008 / 104
1/6
www.sensortechnics.com
BTE6000 / PTU6000...CS Series
Submersible precision stainless steel transmitters
COMMON PERFORMANCE CHARACTERISTICS1
Characteristics
Operating pressure BTEM6100... BTEM6250... BTEM6350... BTEM6500... BTE6001... BTE6002... BTE6005... BTE6010... PTU6002... PTU6003... PTU6005... PTU6010... PTU6015... PTU6030... PTU6050... PTU6100... PTU6150... Thermal effects (0 to 70C)
4
Min.
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Typ.
Max.
100 250 350 500 1 2 5 10 2 3 5 10 15 30 50 100 150
Unit
mbar
bar
p si
Offset Span Offset Span
0.02 0.02 0.03 0.03 0.1 0.1 0.2 0.04 1
0.04 0.04 %FSO/C
(-25 to 0C, 70 to 85C) Non-linearity and hysteresis (BSL) Repeatability Long term stability
6 5
0.25 %FSO
Output noise (0 < f < 1 kHz) Response time (10 to 90 %) Power supply rejection Offset Span
ms %FSO/V
0.05 0.05
August 2008 / 104
2/6
www.sensortechnics.com
BTE6000 / PTU6000...CS Series
Submersible precision stainless steel transmitters
INDIVIDUAL PERFORMANCE CHARACTERISTICS1
0...10 V output (VS = 15 V, RL > 100 k, tamb = 25C)
Characteristics
Zero pressure offset Full scale span
7
Min.
-0.15 9.9
Typ.
0 10.0 100
Max.
0.15 10.1 50
Unit
V mW
Output impedance Power consumption (no load)
1...6 V output (VS = 15 V, RL > 100 k, tamb = 25C)
Characteristics
Zero pressure offset Full scale span7 Full scale output Output impedance Power consumption (no load)
Min.
0.85 4.9
Typ.
1.0 5.0 6.0
Max.
1.15 5.1 50
Unit
V
mW
100
4...20 mA output (VS = 15 V, RL > 100 , tamb = 25C)
Characteristics
Zero pressure offset Full scale span
7
Min.
3.85 15.9
Typ.
4.0 16.0 0.1 260
Max.
4.15 16.1
Unit
mA mW
Output impedance Power consumption (IL = 20 mA)
0...20 mA output (VS = 15 V, RL > 100 , tamb = 25C)
Characteristics
Zero pressure offset Full scale span
7
Min.
-0.15 19.9
Typ.
0 20.0 0.1 260
Max.
0.15 20.1
Unit
mA mW
Output impedance Power consumption (IL = 20 mA)
August 2008 / 104
3/6
www.sensortechnics.com
BTE6000 / PTU6000...CS Series
Submersible precision stainless steel transmitters
ELECTROMAGNETIC CAPABILITY8
Test conditions
Radiated, radio frequency electromagnetic field immunity (RFI) Electrical fast transient / burst immunity (EFT) Electrostatic discharge immunity test (ESD) Immunity to conducted disturbances induced by radio-frequency fields EN61000-4-3: Grade 3 10 V/m, 80 MHz to 1000 MHz 80 % AMC (1 kHz) Grade 3 2 kV Grade 4 8 kV, contact discharge Grade 3 0,15 to 80 MHz 10 V, 80 % AMC (1 kHz)
Criterion
A
Interference
<1 % FSO
EN61000-4-4: EN61000-4-2: EN61000-4-6:
B B
<1 % FSO <1 % FSO
A
<1 % FSO
Specification notes (for all devices):
The package is a all-sealed housing. Gage devices are vented through an integral PE tube of the connecting cable. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagrams. 3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 4. Thermal effects tested and guaranteed from 0 to 70C relative to 25C. All specifications shown are relative to 25C. 5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. 6. Long term stability is the change in output after one year or 1 million pressure cycles. 7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure. 8. Test are in accordance with EN61000-6-2, April 1999. 9. CE-labelling is in accordance with 89/336/EEC. 10. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. 11. Other sealing materials are available on request. 1. 2.
August 2008 / 104
4/6
www.sensortechnics.com
BTE6000 / PTU6000...CS Series
Submersible precision stainless steel transmitters
OUTPUT CHARACTERISTICS
Voltage output versions
Vout 10 V9 8 7 6 5 4 3 2 1 0 20 40 60 80 100 % operating pressure BTE(M)/PTU6...1... BTE(M)/PTU6...0...
Current output versions
lout 20 mA 18 16 14 12 10 8 6 4 2 0 20 40 60 80 100 % operating pressure BTE(M)/PTU6...4... BTE(M)/PTU6...5...
LOAD LIMITATION
0...20 mA output version 4...20 mA ouput version
1400 Ohm 1200 1000 800 600 400 200 operating range
0
5
10
15
20
25
30
35 V
supply voltage
August 2008 / 104
5/6
www.sensortechnics.com
BTE6000 / PTU6000...CS Series
Submersible precision stainless steel transmitters
OUTLINE DRAWING
NOM 151 (5.95) NOM 2000 (78.74) NOM 70 (2.76)
other cable lengths on request O 24 (0.95) O 27 (1.06)
Hydrophobic filter (incl. in delivery)
mass: typ. 350 g (without cable)
dimensions in mm (inches)
ORDERING INFORMATION BTE/PTU
calibration BTE: calibration in bar PTU: calibration in psi mbar-ranges pressure range 100: 250: 350: 500: 001: 002: 005: 010: 0...100 0...250 0...350 0...500 mbar mbar mbar mbar 002: 0...2 psi 003: 0...3 psi 005: 0...5 psi 010: 0...10 psi 015: 0...15 psi 030: 0...30 psi 050: 0...50 psi 100: 0...100 psi 150: 0...150 psi
M
6xxx
x
x
C
x
S
submersible cable length in m cable version output signal 0: 1: 4: 5: 0...10 V 1...6 V 4...20 mA 0...20 mA
0...1 bar 0...2 bar 0...5 bar 0...10 bar
pressure mode G: gage pressure A: absolute pressure (available for pressure ranges from 1 bar/15 psi absolute upwards only!)
Note:
Other pressure ranges and options are widely available. Please contact your nearest Sensortechnics sales representative.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. August 2008 / 104 6/6
www.sensortechnics.com


▲Up To Search▲   

 
Price & Availability of BTEM6350A0CXS

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X